Operation5
5.2.28 Connecting Screw Jacks in Series
The number of screw jacks that can be connected in series is limited by input torque
requirements on the rst worm shaft in the line. For the C-Series the torque on the worm shaft
of the rst screw jack should not exceed 300% of its rated full load torque (this does not include
the 200kN screw jacks which are rated at 200%).
5.2.29 Efciency of a Multiple Screw Jack System
In addition to individual device efciencies, the efciency of the screw jack arrangement must
be taken into consideration. The arrangement efciency allows for misalignment due to slight
deformation of the structure under load, for the losses in couplings, bearings, and for a normal
amount of misalignment in positioning the screw jacks and gearboxes. For efciency values
consult Power Jacks product literature or engineers.
5.2.30 Screw Jack Fitted with 3rd Party Accessories
If your screw jack is tted with a device not manufactured by Power Jacks then please consult
the provided manual for this device.